– Support 8-port Gigabit Ethernet.

– Jumbo frames: Frame sizes up to 9K bytes. The default MTU is 2K bytes.

– MAC table: 8K addresses.

– LEDs: System, Link/Act, PoE, Speed.

– Flash: 256MB.

– CPU: 800 MHz ARM.

– DRAM: 512MB.

– Power: 100 to 240V 50 to 60 Hz, external.

– Unit dimensions (W x D x H): 160 x 128 x 30 mm.

– Unit weight: 0.54kg.

Thông số, tính năng kỹ thuật

 

Performance
Switching capacity and forwarding rate
All switches are wire-speed and nonblocking
– Capacity in millions of packets per second (64-byte packets): 11.90mpps
– Switching capacity in gigabits per second: 16.0Gbps
Layer 2 switching
Spanning Tree Protocol (STP) Standard 802.1d spanning tree support
Fast convergence using 802.1w (Rapid Spanning Tree Protocol [RSTP]), enabled by default
Multiple spanning tree instances using 802.1s (MSTP); 8 instances are supported
Per-VLAN Spanning Tree Plus (PVST+); 126 instances are supported
Rapid PVST+ (RPVST+); 126 instances are supported
Port grouping/link aggregation Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP)
– Up to 4 groups
– Up to 8 ports per group with 16 candidate ports for each (dynamic) 802.3ad Link Aggregation Group (LAG)
VLAN Support for up to 255 active VLANs simultaneously
Port-based and 802.1Q tag-based VLANs
Management VLAN
Guest VLAN
Voice VLAN Voice traffic is automatically assigned to a voice-specific VLAN and treated with appropriate levels of QoS. Voice Services Discovery Protocol (VSDP) delivers networkwide zero-touch deployment of voice endpoints and call control devices
Generic VLAN Registration Protocol (GVRP) and Generic Attribute Registration Protocol (GARP) Protocols for automatically propagating and configuring VLANs in a bridged domain
IGMP (versions 1, 2, and 3) snooping Internet Group Management Protocol (IGMP) limits bandwidth-intensive multicast traffic to only the requesters; supports 255 multicast groups (source-specific multicasting is also supported)
IGMP querier Used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router
HOL blocking Head-of-Line (HOL) blocking prevention
Loopback detection Provides protection against loops by transmitting loop protocol packets out of ports on which loop protection has been enabled. It operates independently of STP
Layer 3 routing
IPv4 routing Wire-speed routing of IPv4 packets
Up to 32 static routes and up to 16 IP interfaces
IPv6 routing Wire-speed routing of IPv6 packets
Layer 3 interface Configuration of Layer 3 interface on physical port, LAG, VLAN interface, or loopback interface
Classless Interdomain Routing (CIDR) Support for CIDR
Dynamic Host Configuration Protocol (DHCP) relay at Layer 3 Relay of DHCP traffic across IP domains
User Datagram Protocol (UDP) relay Relay of broadcast information across Layer 3 domains for application discovery or relaying of Bootstrap Protocol (BootP)/DHCP packets
Security
Secure Sockets Layer (SSL) SSL encrypts all HTTPS traffic, allowing secure access to the browser-based management GUI in the switch
Secure Shell (SSH) Protocol SSH is a secure replacement for Telnet traffic. Secure Copy (SCP) also uses SSH. SSH v1 and v2 are supported
IEEE 802.1X (authenticator role) Remote Authentication Dial-In User Service (RADIUS) authentication, guest VLAN, single/multiple host mode, and single/multiple sessions
STP loopback guard Provides additional protection against Layer 2 forwarding loops (STP loops)
Secure Core Technology (SCT) Ensures that the switch will receive and process management and protocol traffic no matter how much traffic is received
Secure Sensitive Data (SSD) A mechanism to manage sensitive data (such as passwords, keys, and so on) securely on the switch, populating this data to other devices, and secure autoconfig. Access to view the sensitive data as plain text or encrypted is provided according to the user-configured access level and the access method of the user
Trustworthy systems Trustworthy systems provide a highly secure foundation for Cisco products
Run-time defenses (Executable Space Protection [X-Space], Address Space Layout Randomization [ASLR], Built-In Object Size Checking [BOSC])
Port security Ability to lock source MAC addresses to ports and limit the number of learned MAC addresses
RADIUS Supports RADIUS authentication for management access. Switch functions as a client
Storm control Broadcast, multicast, and unknown unicast
DoS prevention Denial-of-Service (DoS) attack prevention
Multiple user privilege levels in CLI Level 1, 7, and 15 privilege levels
Access Control Lists (ACLs) Support for up to 512 rules
Drop or rate limit based on source and destination MAC, VLAN ID or IPv4 or IPv6 address, IPv6 flow label, protocol, port, Differentiated Services Code Point (DSCP)/IP precedence, TCP/UDP source and destination ports, 802.1p priority, Ethernet type, Internet Control Message Protocol (ICMP) packets, IGMP packets, TCP flag; ACL can be applied on both ingress and egress sides
Time-based ACLs supported
Quality of service
Priority levels 8 hardware queues
Scheduling Strict priority and Weighted Round-Robin (WRR) queue assignment based on DSCP and class of service (802.1p/CoS)
Class of service Port based; 802.1p VLAN priority based; IPv4/v6 IP precedence/Type of Service (ToS)/DSCP based; Differentiated Services (DiffServ); classification and re-marking ACLs, trusted QoS
Rate limiting Ingress policer; egress shaping and rate control; per VLAN, per port, and flow based
Congestion avoidance A TCP congestion avoidance algorithm is required to reduce and prevent global TCP loss synchronization
IPv6
IPv6 IPv6 host mode
IPv6 over Ethernet
Dual IPv6/IPv4 stack
IPv6 Neighbor Discovery (ND)
IPv6 stateless address auto configuration
Path Maximum Transmission Unit (MTU) discovery
Duplicate Address Detection (DAD)
Internet Control Message Protocol (ICMP) version 6
IPv6 over IPv4 network with Intrasite Automatic Tunnel Addressing Protocol (ISATAP) support
USGv6 and IPv6 Gold Logo certified
IPv6 QoS Prioritize IPv6 packets in hardware
IPv6 ACL Drop or rate limit IPv6 packets in hardware
Multicast Listener Discovery (MLD v1/2) snooping Deliver IPv6 multicast packets only to the required receivers
IPv6 applications Web/SSL, Telnet server/SSH, Ping, Traceroute, Simple Network Time Protocol (SNTP), Trivial File Transfer Protocol (TFTP), Simple Network Management Protocol (SNMP), Remote Authentication Dial-In User Service (RADIUS), Syslog, DNS client, DHCP client, DHCP autoconfig
IPv6 RFCs supported RFC 4443 (which obsoletes RFC 2463): ICMPv6
RFC 4291 (which obsoletes RFC 3513): IPv6 address architecture
RFC 4291: IPv6 Addressing Architecture
RFC 2460: IPv6 Specification
RFC 4861 (which obsoletes RFC 2461): Neighbor Discovery for IPv6
RFC 4862 (which obsoletes RFC 2462): IPv6 Stateless Address Autoconfiguration
RFC 1981: Path MTU Discovery
RFC 4007: IPv6 Scoped Address Architecture
RFC 3484: Default address selection mechanism
RFC 5214 (which obsoletes RFC 4214): ISATAP tunneling
RFC 4293: Management Information Base (MIB) IPv6: Textual Conventions and General Group
RFC 3595: Textual Conventions for IPv6 Flow Label
Management
Cisco Business Dashboard Support for embedded probe for Cisco Business Dashboard running on the switch. Eliminates the need to set up a separate hardware or virtual machine for the Cisco Business Dashboard Probe on site
Cisco Business mobile app Mobile app for Cisco Business Switch and Wireless products. Helps to set up a local network in minutes and provide easy management at your fingertips
Cisco Network Plug and Play (PnP) agent The Cisco Network Plug and Play solution provides a simple, secure, unified, and integrated offering to ease new branch or campus device rollouts or for provisioning updates to an existing network. The solution provides a unified approach to provision Cisco routers, switches, and wireless devices with a near-zero-touch deployment experience.
Supports Cisco PnP Connect
Web user interface Built-in switch configuration utility for easy browser-based device configuration (HTTP/HTTPS). Supports configuration, wizards, system dashboard, system maintenance, and monitoring
Basic and advanced mode for maximum operational efficiency
SNMP SNMP versions 1, 2c, and 3 with support for traps, and SNMP v3 User-based Security Model (USM)
Remote monitoring (RMON) Embedded RMON software agent supports 4 RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis
IPv4 and IPv6 dual stack Coexistence of both protocol stacks to ease migration
Firmware upgrade Web browser upgrade (HTTP/HTTPS) and TFTP and upgrade over SCP running over SSH
Dual images for resilient firmware upgrades
Port mirroring Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe. Up to 4 source ports can be mirrored to one destination port
VLAN mirroring Traffic from a VLAN can be mirrored to a port for analysis with a network analyzer or RMON probe. Up to 4 source VLANs can be mirrored to one destination port
Dynamic Host Configuration Protocol (DHCP) (options 12, 59, 60, 66, 67, 125, 129, and 150) DHCP options facilitate tighter control from a central point (DHCP server), to obtain IP address, autoconfiguration (with configuration and image file download), DHCP Relay, and host name
Secure Copy (SCP) Securely transfers files to and from the switch
Autoconfiguration with SCP file download Enables mass deployment with protection of sensitive data
Text-editable configs Config files can be edited with a text editor and downloaded to another switch, facilitating easier mass deployment
Smartports Simplified configuration of QoS and security capabilities
Auto Smartports Automatically applies the intelligence delivered through the Smartports roles to the port based on the devices discovered over Cisco Discovery Protocol or LLDP-MED. This facilitates zero-touch deployments
Text view Command-Line Interface (CLI) Scriptable CLI. A full CLI as well as a menu-based CLI is supported. User privilege levels 1, 7, and 15 are supported for the CLI
Localization Localization of GUI and documentation into multiple languages
Login banner Configurable multiple banners for web as well as CLI
Other management Traceroute; single IP management; HTTP/HTTPS; RADIUS; port mirroring; TFTP upgrade; DHCP client; Simple Network Time Protocol (SNTP); cable diagnostics; Ping; syslog; Telnet client (SSH secure support); automatic time settings from Management Station
General
Jumbo frames Frame sizes up to 9K bytes. The default MTU is 2K bytes
MAC table 8K addresses
Discovery
Bonjour The switch advertises itself using the Bonjour protocol
Link Layer Discovery Protocol (LLDP) (802.1ab) with LLDP-MED extensions Link Layer Discovery Protocol (LLDP) allows the switch to advertise its identification, configuration, and capabilities to neighboring devices that store the data in a MIB. LLDP-MED is an enhancement to LLDP that adds the extensions needed for IP phones
Cisco Discovery Protocol The switch advertises itself using the Cisco Discovery Protocol. It also learns the connected device and its characteristics using Cisco Discovery Protocol
Hardware
Power consumption (worst case) System power consumption:
– 110V=7.6W
– 220V=7.6W
Power consumption (with PoE)
Heat dissipation (BTU/hr): 25.93
Ports Total system ports: 8 Gigabit Ethernet
RJ-45 ports: 8 Gigabit Ethernet
Combo ports (RJ-45 + SFP)
USB slot USB Type-A slot on the front panel of the switch for easy file and image management
Buttons Reset button
Cabling type Unshielded Twisted Pair (UTP) Category 5e or better for 1000BASE-T
LEDs System, Link/Act, PoE, Speed
Flash 256MB
CPU 800 MHz ARM
DRAM 512MB
Packet buffer 1.5 MB
Environmental
Unit dimensions (W x D x H) 160 x 128 x 30 mm
Unit weight 0.54kg
Power 100 to 240V 50 to 60 Hz, external
Certification UL (UL 62368), CSA (CSA 22.2), CE mark, FCC Part 15 (CFR 47) Class A
Operating temperature 32° to 122°F (0° to 50°C)
Storage temperature -13° to 158°F (-25° to 70°C)
Operating humidity 10% to 90%, relative, noncondensing
Storage humidity 10% to 90%, relative, noncondensing
Acoustic noise and Mean Time Between Failures (MTBF) Fan (number): Fanless
Acoustic noise: N/A
MTBF at 25°C (hours): 3,277,956

– Bảo hành: 12 tháng.